| Complying with safety regulations |
 |
 |
| Current gas safety regulations*
stipulate that, in many cases where a living flame gas fire is installed
with an open flue, an exterior vent should be fitted. This is a n essential
safety precaution to provide replacement air to the room. |
| Decorative Wall Vent |
 |
| Gazco's decorative wall
vent is designed to be neat and easy to install. Once a cylindrical hole
has been made in the wall with a 5" (125mm) core drill, the durable
polypropylene tube is slid in and cut to length. The interior vent is polished
brass with a no-tarnish finish, while the exterior is weatherproof polyester-coated
steel in a choice of colours. |
Maximum wall thickness: 16"
(400 mm)
Dimensions: 9" x 6" (230 x 150 mm)
Free air: 15 1/2 sq in (100 sq cm) |
| Product code |
Exterior vent colour |
| 8093 |
Black |
| 8094 |
White |
| 8095 |
Brown |
|
A series of knock-out panels,
inserted behind the vent, allows you to select the right opening size for
your fire. |
| Decorative Floor Vents |

Large & Small floor vent |
 |
| A Gazco floor vent is the simple, discreet
solution in rooms with a suspended floor, provided the cavity beneath is
clear through to exterior airbricks. The vent requires a jigsaw and screwdriver
to fit and can be neatly installed with a fitted carpet. Available in two
sizes. |
| Large Floor Vent |
 |
Dimensions 11" x 4 1/4" (230mm
x 110mm)
Free air: 15 1/2 sq in (100 sq cm) |
| Product code |
Vent material/colour |
| 8048 |
Polished brass |
|
| Small Floor Vent |
 |
Dimensions 4 1/2" x 4 1/2"
(114 x 114mm)
Free air: 5 1/2 sq in (36 sq cm) |
| Product code |
Vent material/colour |
| 8250 |
Polished brass |
|
| Exterior ventilation aperture
requirements* of Gazco fires (UK): |
| All VFC
Tapered Fires and VFC Hotbox Fires: |
|
15 1/2 sq in
(100 sq cm) |
| All VFC Convector Fires: |
16" |
2 1/4 sq in (15 sq cm) |
| |
18" |
3 sq in (20
sq cm) |
| |
22" |
4 5/8 sq in (30 sq cm) |
| All RD Versions
of VFC Fires: |
|
None |
| All Riva 67 Cassette Fires
(natural gas): |
|
None |
| N.B. requirements in Eire are
different. * Gas Safety (Installation and Use) Regulations 1984 |
|